The DryVac Unit is the most advantageous dewatering and drying system manufactured by TDM for use in applications where maxium dry solids are needed and or Thermal Drying is an advantage. DryVac Units come in various sizes and supplied in a standardized package up to 5 cubic meter capacity. Any system larger than 5 cubic meters is customed designed to meet the customer requirements. The largest system installed to date has been (4) 17 cubic meter units in a combined operation. DryVac units can exceed this number if required by increaseing unit size(measured in volume capacity) or using multiple units as previously indicated.

DryVac Testing Unit
Model Number DV-06301S-(SI)-0000
Unit Size 1 Cubic Foot Chamber Volume
Type Non-Automated
Plate 630mm (.26 CF)
Number of plates 2-4 as needed

Description of Unit
This is a non automated press designed for use as a test press or limited applications where the customer is willing to be present during the entire stage one process. The customer must also be present to start and stop stage two as well as manually unload the press. The unit uses 480 volt, supplied air, water and can use propane, natural gas or electricity to heat the boiler as desired.
Condensate water is not recovered for reuse due to size

A unit of this size has this basic equipment
• Boiler (280lbs/hr-8HP/268K BTU/hr)
• Vacuum Pump (2HP)
• Cooling Tower (7 Tons/Fan<1 HP/Circulation Pump<1 HP)

--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

DryVac Unit
Model Number DV-08005S-(SI)-0000
Unit Size 5 Cubic Foot Chamber volume
Type Non-Automated
Plate 800mm (.4 CF)
Number of plates 12

Description of Unit
This is a non automated press designed for limited applications where the customer is willing to be present during the entire stage one process. The customer must also be present to start and stop stage two as well as manually unload the press. The unit uses 480 volt, supplied air, water and can use propane, natural gas or electricity to heat the boiler as desired.
Condensate water is not recovered for reuse due to size.

A unit of this size has this basic equipment
• Stainless Steel Filtrate Manifold (not shown)
• Drop Chute (not shown)
• Boiler 280lbs/hr-8HP/268K BTU/hr
• Vacuum Pump 2HP
• Cooling Tower 7 Tons/Fan<1 HP/Circulation Pump <1 HP

Add Text Here...

----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

DryVac Unit
Model Number DV-080010S-(SI)-0000
Unit Size 10 Cubic Foot Chamber volume
Type Automated
Plate 800mm (.4 CF)
Number of plates 25

Description of Unit
This is an automated press operated by use of a PLC (programmable logic computer) and designed for all applications. The customer must be present to start and stop the DryVac Unit, mix chemicals if required as well as manually unload the press. The unit uses 480 volt, supplied air, water and can use propane, natural gas or electricity to heat the boiler as desired.
Condensate water is recovered for reuse.

A unit of this size has this basic equipment
• Stainless Steel filtrate manifold
• PLC (programmable logic computer)
• Boiler feed Pump <1 HP
• Boiler 560lbs/hr-17HP/569K BTU/hr
• Vacuum Pump 3HP
• Cooling Tower 14Tons/Fan<1 HP/Circulation Pump<1 HP

Customer Options
• Type of material feed pump

--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

DryVac Unit
Model Number DV-080015S-(SI)-0000
Unit Size 15 Cubic Foot Chamber Volume
Type Automated
Plate 800mm (.4 CF)
Number of plates 38

Description of Unit
This is an automated press operated by use of a PLC (programmable logic computer) and designed for all applications. The customer must be present to start and stop the DryVac Unit, mix chemicals if required as well as manually unload the press. The unit uses 480 volt, supplied air, water and can use propane, natural gas or electricity to heat the boiler as desired. Condensate water is recovered for reuse.

A unit of this size has this basic equipment
• Stainless Steel filtrate manifold
• PLC (programmable logic computer)
• Boiler Feed Pump <1 HP
• Boiler 880lbs/hr-26HP/870K BTU/hr
• Vacuum Pump 3HP
• Cooling Tower 22 Tons/Fan<1 HP/Circulation Pump<1 HP
Customer Options
• Type of material feed pump
• Conveyor type

----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

DryVac Unit
Model Number DV-120030S-(SI)-0000
Unit Size 30 Cubic Foot Chamber Volume
Type Automated
Plate 1200mm (.8 CF)
Number of plates 38

Description of Unit
This is an automated press operated by use of a PLC (programmable logic computer) and designed for all applications. The customer must be present to start and stop the DryVac Unit, mix chemicals if required as well as unload the press. The unit uses 480 volt, supplied air, water and can use propane, natural gas or electricity to heat the boiler as desired. The unit also comes with a plate shifter. Condensate water is recovered for reuse.

A unit of this size has this basic equipment
• Stainless Steel filtrate manifold
• PLC (programmable logic computer)
• Boiler Feed Pump <1 HP
• Boiler 1200lbs/hr-36HP/1205K BTU/hr
• Vacuum Pump 5HP
• Cooling Tower 30 Tons/Fan<1 HP/Circulation Pump<1 HP
• Plate Shifter

Customer Options
• Type of material feed pump
• Conveyor type

--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------


DryVac Unit
Model Number DV-120040S-(SI)-0000
Unit Size 40 Cubic Foot Chamber Volume
Type Automated
Plate 1200mm (.8 CF)
Number of plates 50

Description of Unit
This is an automated press operated by use of a PLC (programmable logic computer) and designed for all applications. The customer must be present to start and stop the DryVac Unit, mix chemicals if required as well as unload the press. The unit uses 480 volt, supplied air, water and can use propane, natural gas or electricity to heat the boiler as desired. Condensate water is recovered for reuse.

A unit of this size has this basic equipment
• Stainless Steel filtrate manifold
• PLC (programmable logic computer)
• Boiler Feed Pump <1 HP
• Boiler 1600lbs/hr-48HP/1607K BTU/hr
• Vacuum Pump 5HP
• Cooling Tower 40 Tons/Fan<1 HP/Circulation Pump<1 HP
• Plate Shifter

Customer Options
• Type of material feed pump
• Conveyor type

DryVac Unit
Model Number DV-120020S-(SI)-0000
Unit Size 20 Cubic Foot Chamber Volume
Type Automated
Plate 1200mm (.8 CF)
Number of plates 25

Description of Unit
This is an automated press operated by use of a PLC (programmable logic computer) and designed for all applications. The customer must be present to start and stop the DryVac Unit, mix chemicals if required as well as manually unload the press. The unit uses 480 volt, supplied air, water and can use propane, natural gas or electricity to heat the boiler as desired. Condensate water is recovered for reuse.

A unit of this size has this basic equipment
• Stainless Steel filtrate manifold
• PLC (programmable logic computer)
• Boiler Feed Pump <1 HP
• Boiler 880lbs/hr-26HP/870K BTU/hr
• Vacuum Pump 3HP
• Cooling Tower 22 Tons/Fan<1 HP/Circulation Pump<1 HP

Customer Options
• Type of material feed pump
• Conveyor type

---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

DryVac Unit
Model Number DV-150050S-(SI)-0000
Unit Size 50 Cubic Foot Chamber Volume
Type Automated
Plate 1500mm (1.5 CF)
Number of plates 34

Description of Unit
This is an automated press operated by use of a PLC (programmable logic computer) and designed for all applications. The customer must be present to start and stop the DryVac Unit, mix chemicals if required as well as unload the press. The unit uses 480 volt, supplied air, water and can use propane, natural gas or electricity to heat the boiler as desired. Condensate water is recovered for reuse.

A unit of this size has this basic equipment
• Stainless Steel filtrate manifold
• PLC (programmable logic computer)
• Boiler Feed Pump <1 HP
• Boiler 2400lbs/hr-72HP/2410K BTU/hr
• Vacuum Pump 7.5HP
• Cooling Tower 60 Tons/Fan<1 HP/Circulation Pump<1 HP
• Plate Shifter

Customer Options
• Type of material feed pump
• Conveyor type

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

DryVac Unit
Model Number DV-150075S-(SI)-0000
Unit Size 75 Cubic Foot Chamber Volume
Type Automated
Plate 1500mm (1.5 CF)
Number of plates 50

Description of Unit
This is an automated press operated by use of a PLC (programmable logic computer) and designed for all applications. The customer must be present to start and stop the DryVac Unit, mix chemicals if required as well as unload the press. The unit uses 480 volt, supplied air, water and can use propane, natural gas or electricity to heat the boiler as desired. Condensate water is recovered for reuse.

A unit of this size has this basic equipment
• Stainless Steel filtrate manifold
• PLC (programmable logic computer)
• Boiler Feed Pump <1 HP
• Boiler 3200lbs/hr-95HP/3180K BTU/hr
• Vacuum Pump 7.5HP
• Cooling Tower 80 Tons/Fan<1 HP/Circulation Pump 2 HP
• Plate Shifter

Customer Options
• Type of material feed pump
• Conveyor type

----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

DryVac Unit
Model Number DV-1500100S-(SI)-0000
Unit Size 100 Cubic Foot Chamber Volume
Type Automated
Plate 1500mm (1.5 CF)
Number of plates 67

Description of Unit
This is an automated press operated by use of a PLC (programmable logic computer) and designed for all applications. The customer must be present to start and stop the DryVac Unit, mix chemicals if required as well as unload the press. The unit uses 480 volt, supplied air, water and can use propane, natural gas or electricity to heat the boiler as desired. Condensate water is recovered for reuse.

A unit of this size has this basic equipment
• Stainless Steel filtrate manifold
• PLC (programmable logic computer)
• Boiler Feed Pump <1 HP
• Boiler 4000lbs/hr-119HP/3984K BTU/hr
• Vacuum Pump 7.5HP
• Cooling Tower 100 Tons/Fan 2 HP/Circulation Pump 3 HP
• Plate Shifter

Customer Options
• Type of material feed pump
• Conveyor type

--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

More Available DryVac Units
2 Meter (2000mm) Configurations

All additional DryVac Units from this point will contain the normal specified materials as listed below. Please note the standard unit has no additional identifier in the model number. The unit size with X in the model number is designed for an expanded volume. The expandable unit has a DSM built to accept the full complement of plates in the press.

All units are built for chamber volumes expressed in cubic meters

All units of this size have this basic equipment;
• Modified Vacuum System
• Stainless Steel Filtrate Manifold
• Ported Head Plate
• Automated by PLC
• Plate Shifter
• Feed Pump as determined by agreement
• Conveyor

This is an automated press operated by use of a PLC (programmable logic computer) and designed for all applications. The customer must be present to start and stop the DryVac Unit, mix chemicals if required as well as unload the press. The unit uses 480 volt, supplied air, water and can use propane, natural gas or electricity to heat the boiler as desired. Condensate water is recovered for reuse.
Customized site specific installations and service contractsOne cubic meter equals 35 cubic feet

--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------


DryVac Unit
Model Number DV-2000105S-(SI)-0000
Unit Size 3 Cubic Meter Chamber Volume
Type Automated
Plate 2000mm (2.4 CF)
Number of plates 44

• Boiler Feed Pump <1 HP
• Boiler 6000lbs/hr-179HP/5992K BTU/hr
• Vacuum Pump 15 HP
• Cooling Tower 150 Tons/Fan 3 HP/Circulation Pump 7 HP

---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

DryVac Unit
Model Number DV-2000175S-(SI)-0000
Unit Size 5 Cubic Meter Chamber Volume
Type Automated
Plate 2000mm (2.4 CF)
Number of plates 73

• Boiler Feed Pump <1 HP
• Boiler 8000lbs/hr-239HP/8001K BTU/hr
• Vacuum Pump 20 HP
• Cooling Tower 200 Tons/Fan 5HP/Circulation Pump 12 HP

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

DryVac Unit
Model Number DV-2000175XS-(SI)-0000
Unit Size 5-7 Cubic Meter Chamber Volume
Type Automated
Plate 2000mm (2.4 CF)
Number of plates 73- 102

• Boiler Feed Pump <1 HP
• Boiler 10,000lbs/hr-298HP/9976K BTU/hr
• Vacuum Pump 25 HP
• Cooling Tower 250 Tons/Fan 7.5 HP/Circulation Pump 15 HP

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

DryVac Unit
Model Number DV-2000280XS-(SI)-0000
Unit Size 8-10 Cubic Meter Chamber Volume
Type Automated
Plate 2000mm (2.4 CF)
Number of plates 116-145

• Boiler Feed Pump 1 HP
• Boiler 14,000lbs/hr-418HP/13,968K BTU/hr
• Vacuum Pump 40 HP
• Cooling Tower 350 Tons/Fan 15 HP/Circulation Pump 25 HP

-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

DryVac Unit
Model Number DV-2000350S-(SI)-0000
Unit Size 10 Cubic Meter Chamber Volume
Type Automated
Plate 2000mm (2.4 CF)
Number of plates 145

• Boiler Feed Pump 1 HP
• Boiler 14,000lbs/hr-418HP/13,968K BTU/hr
• Vacuum Pump 40 HP
• Cooling Tower 350 Tons/Fan 15 HP/Circulation Pump 25 HP

--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

DryVac Unit
Model Number DV-2000350XS-(SI)-0000
Unit Size 10-12 Cubic Meter Chamber Volume
Type Automated
Plate 2000mm (2.4 CF)
Number of plates 145-175

• Boiler Feed Pump 1 HP
• Boiler 18,000lbs/hr-522HP/17,465 BTU/hr
• Vacuum Pump 50 HP
• Cooling Tower 450 Tons/Fan 25 HP/Circulation Pump 40 HP

-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

DryVac Unit
Model Number DV-2000350XS-(SI)-0000
Unit Size 13-14Cubic Meter Chamber Volume
Type Automated
Plate 2000mm (2.4 CF)

Number of plates 189- 204
• Boiler Feed Pump 1 HP
• Boiler 20,000lbs/hr-580HP/19,465K BTU/hr
• Vacuum Pump 75 HP
• Cooling Tower 500 Tons/Fan 40 HP/Circulation Pump 40 HP

----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

DryVac Unit
Model Number DV-2000595S-(SI)-0000
Unit Size 17 Cubic Meter Chamber Volume
Type Automated
Plate 2000mm (2.4 CF)

Number of plates 250
• Boiler Feed Pump <1 HP
• Boiler 24,000lbs/696HP/23,287K BTU/hr
• Vacuum Pump 100 HP
• Cooling Tower 600 Tons/Fan 50 HP/Circulation Pump 60 HP

Add Text Here...

---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------